An RCD cuts power before current runs through a person. Where the Latvian code requires one, which type to pick and what to do when it trips.
Sep 17, 2026 · NextTek
Short answer: an RCD (noplūdes automāts in Latvian) compares the current going out on the phase with the current coming back on the neutral. If the difference exceeds its setting, say 30 mA, it cuts the circuit in a fraction of a second. That difference is current escaping through a damp wall, a faulty device or a person.
A normal breaker trips when the current is too high for the wire: overload or short circuit. It does not react to 30 mA flowing through a person. An RCD, in turn, does not protect against overload. So a panel needs both, or one combined device called an RCBO.
Since the 2025 amendments, LBN 261-15 requires:
The code covers design and installation, so new wiring and rebuilds. It does not force you to redo an existing flat. But if a renovation replaces the panel or adds new circuits, the new part already has to comply.
Point 28.3 says to choose the type by the connected equipment. In plain terms:
The device manual has the final word. If a charger or inverter manual says “type B”, a type A RCD may fail to trip there.
Switch everything off the circuit and reset the RCD. Then plug devices back one by one. The usual culprits are a water heater with an old element, a washing machine, a dishwasher and an extension lead on the balcony.
An outdoor socket after rain, a bathroom fan, a basement light. If it trips only after rain, the fault is usually moisture, not the RCD.
If the RCD trips again straight away, the circuit has a leak. Do not hold the lever up or tape it. That is exactly what it protects you from.
In old wiring the neutrals of two circuits are sometimes joined. Then the RCD trips when a light goes on in another room. An electrician finds it by measuring, not guessing.
An RCD has a T or Test button. It creates an artificial leak, and the RCD must trip. Manufacturers recommend pressing it regularly, often every six months; the manual says exactly. If it does not trip after T, replace it.
The device itself is not expensive. The work depends on the panel: whether there is room, whether the circuit neutrals are separated and whether the old panel is safe at all. An exact price is possible after seeing the panel or a good photo.
A NextTek electrician looks at the panel, fits an RCD of the right type and finds out why it trips. More on the electrician page. If the wiring is old, start with a wiring inspection.
Sources: LBN 261-15 (points 28.1–28.3, amended by Cabinet Regulation No. 355 of 17 June 2025). Checked in October 2026.